Guides

Plain advice on choosing lighting, fans, switches and protection, with the terms explained.

16 guides43 terms explained

Lighting

Match the cap, pick brightness in lumens, then choose the colour of light for the room.

  • Check the cap first: E27 screw, B22 bayonet, E14 small screw or GU10 two-pin.
  • Choose by lumens, not watts. About 800 lm replaces an old 60W bulb.
  • 3000K is warm, 4000K is neutral, 6500K is daylight white.
  • Only use a dimmable bulb on a dimmer switch.

Read the full guide2 min read

Measure the ceiling hole, decide between wide and focused light, and pick the colour for each room.

  • Measure the cut-out (the hole in the ceiling) before you buy a replacement.
  • Downlights spread light; eyeball and track spotlights aim it at walls, shelves and displays.
  • 3-colour (3CCT) models let you choose 3000K, 4000K or 6500K after installation.
  • Bathrooms and covered porches need a moisture-rated (IP44 or higher) fitting.

Read the full guide2 min read

T8 or T5, tube or complete batten, and what to ask before changing an office or shop over to LED.

  • T8 tubes are 26 mm across; T5 tubes are 16 mm. They are not interchangeable.
  • Length matters: 2 ft (about 600 mm) and 4 ft (about 1,200 mm) are the common sizes.
  • Some LED tubes need the old ballast or starter removed. Have an electrician rewire the fitting.
  • A complete LED batten or panel is often simpler than converting an old fitting.

Read the full guide2 min read

Size the light by lumens and mounting height, check the IP rating, and decide on the beam.

  • Floodlights light outdoor areas from a wall or pole; high bay lights hang from tall ceilings.
  • Compare lumens, not watts. Datasheets list the lumen output per model.
  • Outdoors, look for IP65 or IP66.
  • Mounting height and spacing decide how many lights you need. Send us the area and height for a suggestion.

Read the full guide2 min read

Look past the headline wattage: the panel, the battery and the lumen figure decide how a solar light performs.

  • The big wattage in a solar light's name is not the same as the light output. Compare lumens and the battery.
  • A larger panel and battery give longer, brighter nights.
  • Mount the panel where it gets direct sun for most of the day.
  • Outdoors, look for IP65 or higher.

Read the full guide2 min read

Two track systems that look alike but cannot be mixed. Here is how to pick one before you buy lights.

  • A normal track carries mains power. A 48V magnetic track carries low-voltage DC from its own power supply.
  • Magnetic lights snap on with magnets. Normal track lights twist into the track with an adapter.
  • Magnetic lights do not fit a normal track, and normal lights do not fit a magnetic track.
  • Add up the watts of all lights on one magnetic track, then add about 20% to size the power supply.

Read the full guide2 min read

A strip, a 24V power supply and a switch. How to put the set together so it is bright, safe and easy to service.

  • A kit is three parts: the COB strip, a 24V power supply, and a switch or sensor.
  • Add up the strip watts, then add 20%. Pick the next power supply size up.
  • Keep the strip and power supply on the same voltage. 24V strip needs a 24V supply.
  • Leave the power supply where you can reach it. Do not bury it.

Read the full guide2 min read

Fans, power and protection

Pick the blade size for the room, check the ceiling height, and choose between AC and DC motors.

  • Bigger rooms need bigger blades: roughly 42 to 48 inch for bedrooms, 56 to 60 inch for living rooms.
  • Keep the blades at least about 2.1 m (7 ft) above the floor.
  • DC motor fans use less power and usually come with a remote; AC fans often use a wall regulator.
  • Fans with lights need a suitable switch and wiring at the ceiling point.

Read the full guide2 min read

Room volume times air changes per hour gives the airflow you need. Then add some for the duct.

  • Room volume in cubic metres x air changes per hour x 0.59 = CFM needed.
  • Bathrooms and toilets: about 8 air changes per hour. Home kitchens: 10 to 15.
  • Long or bendy ducts cut the airflow. Add 25 to 50% for them.
  • Put the fan far from the door so fresh air crosses the room.

Read the full guide2 min read

Malaysia uses the 13A three-pin plug. Choose by gang count, finish and series, and buy approved products.

  • Malaysia uses the 13A square three-pin plug and socket (BS 1363 type).
  • “Gang” is the number of switches on one plate; “way” means a switch that works with another for two-point control.
  • Keep one series and colour per room so plates match.
  • Look for approval marks such as SIRIM and the Energy Commission (ST) label on wiring accessories.

Read the full guide2 min read

A track you mount once, with sockets you slide to wherever you need them. What it does well, and what it should not be asked to do.

  • Fix the track once, then slide sockets along it. No more cutting new holes.
  • Good for kitchen counters, study desks, TV walls and shop counters.
  • The track is for dry areas. Keep it away from the sink and from splashes.
  • Count the heaters and kettles that run at the same time, not just the sockets.

Read the full guide2 min read

The pump decides how the shower feels. Here is how to choose, and what your wiring has to handle.

  • No pump: simplest, works well when your water pressure is already good.
  • A pump boosts weak pressure. A DC pump is usually quieter and smoother than an AC pump.
  • Our models run 3.6 to 4.25 kW, about 15 to 18 A. Give the heater its own circuit.
  • Wiring, earthing and the breaker are for a registered electrician.

Read the full guide2 min read

A simple guide to the usual cable size for lights, sockets and a water heater, and why the breaker must match the cable.

  • Lights usually use 1.5 mm². Normal 13A socket circuits usually use 2.5 mm².
  • A water heater of 3.6 to 4.25 kW usually needs 4 mm² or bigger, on its own breaker.
  • The breaker protects the cable. Never fit a bigger breaker on a thinner cable.
  • Long runs lose voltage, so ask your electrician to go up a size.

Read the full guide2 min read

Breakers protect cables from overload; RCCBs protect people from earth leakage. Here is how to tell them apart.

  • An MCB trips on overload and short circuit. It protects the cable.
  • An RCCB trips when current leaks to earth. It protects people from electric shock.
  • An RCBO combines both in one module for a single circuit.
  • Ratings: amps (e.g. 6A, 16A, 32A), poles (1P, 2P, 4P) and, for RCCBs, sensitivity (e.g. 30 mA, 100 mA).

Read the full guide2 min read

How to tell which supply you need, and what to ask for when you buy a distribution board.

  • Most homes run on single phase. TNB gives single phase for demand up to about 12 kVA.
  • Many air-conditioners, a big water heater or three-phase machines push you towards three phase.
  • Count the ways you need, then add a few spare ways.
  • Ask for the kA rating, the RCCB and surge protection. Confirm the supply with TNB and your electrician.

Read the full guide2 min read

Visiting from Singapore

We are in Taman Bukit Indah, about 10 minutes from the Second Link. Send your list on WhatsApp first and the trip is short.

  • We are about 10 minutes from the Second Link (Tuas) in Taman Bukit Indah, Iskandar Puteri.
  • Malaysia and Singapore both use the 13A flat three-pin plug at about 230V and 50Hz.
  • Send your list on WhatsApp first. We check the stock and have it ready.
  • Check Singapore's own rules for what you bring back and who may install it.

Read the full guide2 min read

Calculators

Words on the box, explained

The terms you'll see on datasheets and boxes, in plain words.

Full glossary

Come to the counter

D-One Electrical is in Taman Bukit Indah, Iskandar Puteri, minutes from the Second Link. Bring the model number or a photo and we'll find it.

No. 11, 11A & 11B, Jalan Indah 15/2, Taman Bukit Indah, Iskandar PuteriMon to Fri 8am to 5pm, Sat 8am to 4pm. Closed Sundays and public holidays.

Prices change with stock and quantity, so we quote on request.

WhatsApp for a quote